title: "CVE-2026-55681: WeGIA - SQL Injection"
description: "WeGIA < 3.8.6 contains a SQL injection caused by a second extract($_REQUEST) overwriting sanitized id_produto in web/html/matPat/restaurar_produto_desocultar.php, letting authenticated users execute arbitrary SQL to extract or modify data."
url: https://panop.io/threat-heartbeat/CVE-2026-55681/
---

# CVE-2026-55681 WeGIA - SQL Injection

WeGIA < 3.8.6 contains a SQL injection caused by a second extract($\_REQUEST) overwriting sanitized id\_produto in web/html/matPat/restaurar\_produto\_desocultar.php, letting authenticated users execute arbitrary SQL to extract or modify data.

CVSS base score 8.8 /10

High

CISA KEV

Not listed

Public exploit

None known

Authentication

Required

[View the NVD record ↗](https://nvd.nist.gov/vuln/detail/CVE-2026-55681)

## Details

Type

SQL Injection

Impact

SQL Injection, Information Disclosure, Data Tampering

CVSS vector

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Published

14 October 2026

Updated

15 October 2026

Weakness

[CWE-89](https://cwe.mitre.org/data/definitions/89.html)

## Vendor fix

Upgrade to version 3.8.6.

Patching closes this CVE. It does not tell you which of your systems run the affected version, or what else is exposed alongside them.

## References

- [https://nvd.nist.gov/vuln/detail/CVE-2026-55681](https://nvd.nist.gov/vuln/detail/CVE-2026-55681)
- [https://github.com/LabRedesCefetRJ/WeGIA/releases/tag/3.8.6](https://github.com/LabRedesCefetRJ/WeGIA/releases/tag/3.8.6)
- [https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-9q8x-jqpj-23xp](https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-9q8x-jqpj-23xp)
- [https://github.com/LabRedesCefetRJ/WeGIA/commit/8fa3dfcd71c2058c3b6127fdb40d3f1ec068be3e](https://github.com/LabRedesCefetRJ/WeGIA/commit/8fa3dfcd71c2058c3b6127fdb40d3f1ec068be3e)
- [https://github.com/LabRedesCefetRJ/WeGIA/issues/99](https://github.com/LabRedesCefetRJ/WeGIA/issues/99)
- [https://github.com/LabRedesCefetRJ/WeGIA/pull/1705](https://github.com/LabRedesCefetRJ/WeGIA/pull/1705)

[← All CVEs](https://panop.io/threat-heartbeat/)

## What this record can't tell you

- Whether you run the affected software, and where
- Whether an attacker can actually reach and exploit it
- The misconfigurations that never get a CVE number
- What it would cost the business, ranked into what to fix first

Panop answers these inside your environment, for this CVE and every other finding.

[Book a demo](https://panop.io/demo)